دوره 1، شماره 2 - ( 9-1393 )                   جلد 1 شماره 2 صفحات 48-58 | برگشت به فهرست نسخه ها


XML English Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Hoseini S J, Mosavi Gazafroudi S M. A Comprehensive Method for Detection of Induction Motors Bearing Faults . IJRARE. 2014; 1 (2) :48-58
URL: http://ijrare.iust.ac.ir/article-1-56-fa.html
A Comprehensive Method for Detection of Induction Motors Bearing Faults . دانشگاه علم و صنعت ایران. 1393; 1 (2) :48-58

URL: http://ijrare.iust.ac.ir/article-1-56-fa.html


چکیده:   (100 مشاهده)
In this paper, some deficiencies of previously conducted studies are pointed out. These are including unreliability, dependent to motor and bearing specifications, lack of precision, drawbacks of experimental tests and etc. Here some important works will be reviewed. The proposed method which is based on wavelet decomposition and tracing the trend of statistical features variations, has overcame most of these deficiencies. Experimental results validated the proposed method. Finally, an approach to enhance detectability and precision in realistic industrial applications which is based on comparing power factor and temperature of tested and industrial application cases, will be presented.
متن کامل [PDF 1012 kb]   (66 دریافت)    
نوع مطالعه: پژوهشي | موضوع مقاله: عمومى

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
کد امنیتی را در کادر بنویسید

کلیه حقوق این وب سایت متعلق به دانشگاه علم و صنعت ایران می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2015 All Rights Reserved | International Journal of Railway Research

Designed & Developed by : Yektaweb